மின்துறையால் பொருத்தப்படும் புதிய மின்-மீட்டர் பற்றிய விபரம் போதிய அளவில் பொதுமக்களுக்கு இல்லை. தெரிந்துகொள்ள வேண்டியது அவசியம், தெரிந்தால் மட்டுமே , தவறுகள் நடக்கும் பட்சத்தில் சட்டப்படி கேள்வி கேட்க முடியும் .

Image 1 (88888888 / All Icons Lit): LCD display self-test showing every segment and symbol on the screen to confirm the display is working properly.

Image 2 (Inst FQ — 49.90): Instantaneous grid frequency measured in Hertz (49.90 Hz, normal range is 50.00 Hz).

Image 3 (Inst PF — 0.96): Instantaneous Power Factor (0.96), showing how efficiently your appliances are using electrical power right now (1.00 is ideal)

Image 4 (Inst — 0.61 kVA): Instantaneous Apparent Power load currently running across all three phases.

Image 5 (Inst — 0.61 kW): Instantaneous Active Power load currently running across all three phases.

Image 6 (N — 0.59 A): Live current flowing through the Neutral wire (0.59 Amps).

Image 7 (B — 1.64 A): Live current flowing through the Blue (B) phase (1.64 Amps).

Image 8 (Y — 0.74 A): Live current flowing through the Yellow (Y) phase (0.74 Amps).

Image 9 (R — 0.48 A): Live current flowing through the Red (R) phase (0.48 Amps).

Image 10 (B — 253.18 V): Live line-to-neutral voltage on the Blue (B) phase (253.18 Volts).

Image 11 (Y — 250.34 V): Live line-to-neutral voltage on the Yellow (Y) phase (250.34 Volts).

Image 12 (R — 253.36 V): Live line-to-neutral voltage on the Red (R) phase (253.36 Volts).

Image 13 (POSTPAID): Confirms your smart meter is configured for Postpaid billing rather than prepaid recharge mode

Image 14 (IP-H0 PF Bill — 0.98): Average Power Factor recorded during the most recent completed billing cycle (H0).

Image 15 (IP-H0 MD Time — 01:00:00):

Image 16 (IP-H0 MD Date — 02:10:26): The date (2 October 2026) when your peak apparent demand (MD kVA) occurred in the last billing cycle.

Image 17 (IP-H0 MD Time kW — 01:00:00): The time (1:00 AM) when your peak active demand (MD kW) occurred in the last billing cycle.

Image 18 (Ld-rCt-4 — 49.14 kVArh): Cumulative Leading Reactive Energy (Quadrant 4), usually caused by capacitive loads or lightly loaded lines.

Image 19 (LG-rCt-1 — 133.60 kVArh): Cumulative Lagging Reactive Energy (Quadrant 1), caused by inductive loads like motors, pumps, and air conditioners (same screen as your very first standalone photo).

Image 20 (IP-Cu — 1780.22 kVAh): Cumulative Import Apparent Energy (1780.22 kVAh)

Image 21 (IP-H0 MD Date kW — 02:10:26): The date (2 October 2026) when your peak active demand (MD kW) occurred in the last billing cycle.

Image 22 (IP-H0 MD — 5.45 kW): Maximum Active Power Demand (5.45 kW) reached during the last completed billing cycle (H0).

Image 23 (IP-Cu-Fd — 1764.81 kWh): Cumulative Forward Active Energy (1764.81 kWh), which records total forward active units including any reverse-current/tamper conditions.

Image 24 (IP-Cu — 1762.17 kWh): Main Cumulative Import Active Energy (1762.17 kWh)

Image 25 (FOR Ard): Indicates the meter is configured in Forward-Only (Unidirectional) metering mode (meaning any reverse current flow is added forward rather than exported, as opposed to net metering).

Image 26 (S.No — PA2033262): Your meter’s unique Serial Number (PA2033262).

Image 27 (RTC Time — 20:23:15): Internal Real-Time Clock showing the time the photo was taken (8:23:15 PM).

Image 28 (RTC Date — 20:10:26): Internal Real-Time Clock showing the date the photo was taken (20 October 2026).

Image 29 (PHSQ rYb): Phase Sequence (R-Y-B) verification, confirming that all three phases (R, Y, B) are connected in the proper sequence.

Image 30 (OK CnCH): Connection Check (OK), confirming the internal voltage/phase connection test passed.